Skip to main content
Tekron & Trekre - Industrial valves
qiang@tekron.com.cn +86 510 88232303
Jiangsu Tekron

Industrial Valve Manufacturer

Enquiry

JIS 10K Flanged Lift Check Valve with Bypass

JIS 10K Flanged Lift Check Valve with Bypass

Product parameters

The main disc lifts under fluid differential pressure. The handwheel operates the bypass line to adjust bypass flow and the associated pressure condition; it is not the normal drive for the main check disc.

Typical selection options

ProductJIS 10K Flanged Lift Check Valve with Bypass
Nominal sizeDN50–DN600
Pressure classJIS 10K
Body materialCast iron, ductile iron, steel or stainless options
Lining / seatSoft or metal seat options
ConnectionJIS 10K flanges
OperationFluid differential pressure; bypass handwheel
Temperature0–80°C
MediaWater and circulation water
Design / connection standardJIS B 2002 / JIS B 2220
Pressure and closure testJIS B 2003

Series reference options, not all possible combinations of size, material, pressure and temperature. Allowable working pressure varies with temperature; select the build when ordering.

JIS 10K Flanged Lift Check Valve with Bypass
Existing product photo

Installation and selection

Typical water-service reference: 0–80°C. Select different seals for higher temperatures. Check the flow arrow, installation orientation and bypass connections. Manual bypass adjustment is not automatic constant-pressure regulation.

Purchasing questions

What does the handwheel control?

It adjusts the bypass opening; the main check function remains fluid-operated.

What should an enquiry include?

Size, JIS 10K connections, medium, temperature, pressure, mounting orientation and bypass requirements.

Tekron & Trekre

Check valve

01 Why are check valves usually installed at the pump outlet?
The installation of check valves at the pump outlet is mainly to prevent reverse flow after the pump stops and to reduce the impact of reverse flow and pressure fluctuations on the pump and the system. The specific installation position and valve type should be determined through system hydraulic calculations, pump type, flow rate, water hammer risk, installation direction, and maintenance conditions; whether to install a bottom valve or other check devices at the pump inlet is another issue related to the system design.

Discuss your valve configuration and quotation

Complete the details you know; leave unknown operating conditions blank. Name, email and enquiry are required. Phone is optional.

Add operating and connection requirements (optional)

Include units. PN and ASME Class are separate designations, not a fixed conversion.

Email drawings, nameplate photos or technical files with the product link. This form does not accept attachments. [email protected]