N6 High-Purity Nickel Flanged Y-Strainer

N6 High-Purity Nickel Flanged Y-Strainer

Product parameters

Series selection options

Body materialN6 high-purity nickel
Nominal sizeDN15–DN300 available
Pressure classPN16 or PN25 available

Smaller or larger sizes outside the listed range can be evaluated for custom manufacture and tooling. The listed sizes are not the limits of custom capability; supply is subject to an agreed design and quotation.

N6 high-purity nickel flanged Y-strainer for caustic-service piping

Technical specifications — reference options; select against the actual product data

ItemSpecification
Nominal sizeDN15–DN300 available
Pressure classPN16 or PN25 available
Body materialN6 high-purity nickel
Screen materialSelected for the filtration requirements
Filtration finenessCustomized to process requirements; mesh options available
Service mediaCaustic alkalis, alkaline solutions and salt solutions
Fluid temperatureSelected for the service conditions and configuration
ConstructionY-type with inclined screen
ConnectionFlanged

The role of a Y-strainer in alkaline-service piping

In caustic and alkaline-solution systems, welding debris, rust flakes and crystals can cause sticking, wear, equipment damage or production interruptions if they reach downstream pumps, valves or flowmeters. A Y-strainer retains these solids in its screen to help protect downstream equipment.
This flanged Y-strainer combines filtration with an alkali-resistant N6 high-purity nickel body. The screen is selected for the filtration duty. It is intended for caustic and salt-solution service, including piping in chlor-alkali and alkali-production plants.

N6 high-purity nickel for alkali-resistant strainer bodies

N6 is a high-purity nickel grade in the commercially pure nickel family. Its exact composition must follow the supplied material standard and certificate. Material characteristics include:
  1. Resistance to caustic alkalis: Pure nickel has good resistance to caustic alkalis such as sodium hydroxide and potassium hydroxide, with advantages in hot alkaline service.

  2. Resistance to salt solutions: Good corrosion resistance in a range of salt solutions and neutral brines.

  3. Low impurity content: High purity reduces the adverse effects of impurity elements on corrosion resistance.

  4. Formability and fabrication: Suitable for fabricating strainer housings, flanges and screen components.

Pure nickel has limited resistance to oxidizing acids such as nitric acid and to strongly oxidizing media. Avoid selecting this N6 strainer for such service; establish the fluid composition before selection.

Y-strainer construction and operation

A Y-strainer is named after its Y-shaped body. Its main components are the housing, flange connections and an inclined screen:
  1. Fluid enters the inlet, passes through the screen and leaves through the outlet. Solids are retained inside the screen.

  2. The inclined screen provides a relatively large filtration area and relatively low pressure loss.

  3. When debris accumulates, isolate the piping section, depressurize, drain and safely handle the fluid. Then open the cover and clean the screen according to the instructions. Never remove the cover under pressure.

  4. Different screen mesh counts can be selected for the required process filtration.

Y-strainers are compact and widely used in industrial piping. Horizontal or vertical installation must suit the specified flow direction and service requirements.

Key features

  1. N6 high-purity nickel body with a duty-selected screen, for caustic and salt-solution resistance in alkaline piping.

  2. Compact Y-shaped construction with a relatively large screen area and relatively low pressure loss.

  3. The inclined screen is accessible for removal and cleaning, helping reduce maintenance costs.

  4. Flange connections facilitate installation, removal and pipeline maintenance.

  5. Filtration fineness can be customized for the required process cleanliness.

  6. Helps protect downstream pumps, valves and instruments and reduce the risk of equipment faults.

Applications and selection

Applications include chlor-alkali, alkali production, salt chemicals, chemical fibres and metallurgy, particularly:
  • Filtration of caustic solutions such as sodium hydroxide and potassium hydroxide.

  • Protection of equipment downstream of alkaline-solution evaporation, concentration and transfer systems.

  • Process piping carrying salt solutions or brine.

  • Duties requiring alkali resistance beyond that of an ordinary stainless-steel strainer.

Check the following when selecting a configuration:
  1. Fluid composition: Pure nickel resists alkalis but not oxidizing acids. Check for strongly oxidizing constituents before selection.

  2. Filtration fineness: Select the mesh count for downstream equipment, balancing particle retention against pressure loss.

  3. Temperature and pressure: Check body and seal suitability for hot alkaline service, and select the pressure class for the system.

  4. Installation direction: Follow the specified flow direction so that debris is retained inside the screen and can be removed.

  5. Flange standard: Flange pressure class and facing must match the piping.

Selection summary

The N6 high-purity nickel flanged Y-strainer combines an alkali-resistant body with a Y-type screen arrangement for caustic and salt-solution piping. Select it as part of the complete piping system, considering pipe materials, pumps and valves. Qualified personnel should confirm the configuration against the fluid and process conditions.

N6 high-purity nickel flanged Y-strainer



Tekron & Trekre

Valve

01 How should one compare valve brands and suppliers?
The manufacturing standards, material grades, pressure levels, leakage requirements, inspection documents, supply boundaries, delivery cycles and after-sales responsibilities should be compared based on the same technical conditions. If the technical conditions are different, comparing only the brand names or quotations would not be comparable.

Discuss your valve configuration and quotation

For overseas project enquiries: Trekre.

Complete the details you know; leave unknown operating conditions blank. Name, email and enquiry are required. Phone is optional.

Add operating and connection requirements (optional)

Include units. PN and ASME Class are separate designations, not a fixed conversion.