Application and package scope
Compressed air drives the piston racks, turning the output pinion through a partial rotation. Both opening and closing require air supply. The actuator can operate ball valves, butterfly valves and other compatible valves after matching the load and control circuit.
Configuration options and purchasing checks
| Item | Configuration |
|---|---|
| Drive mechanism | Pistons, racks and output pinion |
| Action | Double-acting; air-driven in both directions |
| Rotation reference | Typically 90°; check the actual travel for the selected model |
| Air-supply reference | Typically 0.4~0.7MPa; maximum permissible supply pressure per model nameplate |
| Operating time | Depends on model, load, air supply and pneumatic accessories |
| Accessory options | Solenoid valve, end-position feedback, filter regulator, speed control and position-holding arrangement |
Check torque at the minimum available air pressure
The minimum site pressure may be lower than the air-station setting. Compare actuator torque with the valve operating load at the pressure available at the actuator inlet. Also check the flow capacity of the tubing and solenoid valve.
Air-failure behaviour depends on the complete circuit
A double-acting actuator does not inherently provide spring return. Valve load and residual pressure can affect its position after air failure. Do not assume fail-close or position holding; specify and validate the appropriate pneumatic circuit if holding position is required.
Check mechanical interfaces and accessories separately
Match the output shaft, mounting flange, coupling and rotation direction to the valve. The solenoid valve switches air paths, limit switches report end positions, and a positioner controls position. These accessories perform different functions and cannot substitute for one another.
Enquiry and supply documents
Provide the mating valve, load or service conditions, interface drawing, utility and control requirements, environment and quantity. Jiangsu Tekron Flow Control Valve Co., Ltd. can discuss a suitable configuration on this basis. The final model, accessories, drawings and inspection requirements are subject to the agreed technical specification.
Product photographs illustrate a configuration; not every accessory shown is automatically included in the supply.
Related categories:Valve actuators and accessories · Electric actuated valves · Pneumatic valves · Control valves
Selection questions
Does a double-acting actuator always stay in position after air failure?
No. Its final position depends on the load, air circuit and accessories. Define any position-holding requirement and provide an appropriate circuit.
Should selection use compressor discharge pressure or actuator inlet pressure?
Use the minimum available pressure at the actuator inlet, allowing for pressure losses in tubing, solenoid valves and simultaneous operation.
Are solenoid valves and limit switches included as standard?
Not automatically. Specify the accessory quantities, models, voltages, feedback types and mounting hardware in the supply list.