Application and package scope
For remote on/off operation of ball valves, butterfly valves and other part-turn valves. A reduction gear transmits motor output to the valve stem. Select for the valve operating load, required rotation and site power supply, for circuits requiring fully open, fully closed and end-position feedback.
Configuration options and purchasing checks
| Item | Configuration |
|---|---|
| Motion | Part-turn, typically approximately 90°; actual rotation per valve and actuator data |
| Control duty | On/off isolation; not supplied as a continuous-modulating version |
| Power-supply options | AC220V or AC380V; select any DC24V option for the specific series |
| Feedback | Open and closed end positions; contacts and wiring per configuration list |
| Local operation | Manual mechanism and mode changeover per selected version |
| Selection basis | Breakaway, running and closing torque, and the valve's allowable input load |
Match output to the valve load
Breakaway, running and final seating torques may differ and must each be checked against the valve data. The actuator must complete the required movement without exceeding the allowable loads of the stem, coupling or seat. Equal valve sizes do not establish that the same actuator size is suitable.
Specify power and control interfaces separately
Motor power, on/off commands and feedback contacts are separate interfaces. State voltage, frequency, control-cabinet command type, feedback requirements and operating frequency separately. A voltage alone does not define the control requirements.
Replacement interfaces and power failure
For replacement, check the mounting flange, output bore, coupling, travel and rotation direction. Do not assume that a conventional on/off actuator returns on power failure. If movement after power loss is required, specify energy storage, backup power or another failure-response arrangement separately.
Enquiry and supply documents
Provide the mating valve, load or service conditions, interface drawing, utility and control requirements, environment and quantity. Jiangsu Tekron Flow Control Valve Co., Ltd. can discuss a suitable configuration on this basis. The final model, accessories, drawings and inspection requirements are subject to the agreed technical specification.
Product photographs illustrate a configuration; not every accessory shown is automatically included in the supply.
Related categories:Valve actuators and accessories · Electric actuated valves · Pneumatic valves · Control valves
Selection questions
Can an open-position signal prove that the valve is shut tight?
No. An end-position signal reports actuator position. Seat tightness still requires testing of the complete valve under the agreed conditions.
Can a ball valve and butterfly valve of the same size use the same actuator?
Not on size alone. Check the load, rotation, interface and allowable input load of each valve before deciding whether one actuator size is suitable.
Should an enquiry state both power and control voltages?
Yes. List motor power, control commands and feedback contacts separately, and use the wiring diagram for the selected actuator.